CVE-2023-52891
Siemens SIMATIC Energy Manager Basic: Improperly Controlled Sequential Memory Allocation
Description
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.
Severity (CVSS)
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
- Attack vector
- network: an attacker can reach the vulnerable part over the network, often from the internet
- Attack complexity
- low: an attack works without special conditions
- Privileges required
- none: the attacker does not need an account
- User interaction
- none: nobody has to click or open anything
- Scope
- unchanged: the damage stays inside the vulnerable component
- Impact
- confidentiality none, integrity none, availability low: what an attacker can read (confidentiality), change (integrity) or stop (availability)
Exploitation
EPSS 0.71%: the probability of exploitation activity in the next 30 days, from the EPSS model of FIRST. The score is higher than 49.0% of all scored CVEs. Scores of 29 Nov 2026.
The assessment of CISA (SSVC, 9 Jul 2024):
- Exploitation
- none: CISA did not find evidence of exploitation or a public proof of concept
- Automatable
- yes: an attacker can automate the attack across many targets
- Technical impact
- partial: limited control or limited data
Weakness
- CWE-1325 Improperly Controlled Sequential Memory Allocation
Affected products
As the CNA lists them.
| Product | Versions |
|---|---|
| SIMATIC Energy Manager Basic |
affected before V7.5
Other versions: unknown
|
| SIMATIC Energy Manager PRO |
affected before V7.5
Other versions: unknown
|
| SIMATIC IPC DiagBase |
affected all versions
Other versions: unknown
|
| SIMATIC IPC DiagMonitor |
affected all versions
Other versions: unknown
|
| SIMIT V10 |
affected all versions
Other versions: unknown
|
| SIMIT V11 |
affected before V11.1
Other versions: unknown
|
Is my server affected?
This CVE is in SIMATIC Energy Manager Basic of Siemens, which Linux distributions and language package managers do not ship. The advisory of the vendor is in the references below.
Vulnpocalypse matches the package lists of Linux servers and containers against the Trivy vulnerability database, which does not list this product.
References
Other references
- https://cert-portal.siemens.com/productcert/html/ssa-088132.html cert-portal.siemens.com
Source: the record CVE-2023-52891 of the CVE List (CVE Program), CVE Terms of Use; the CISA KEV catalog and the CISA ADP container; EPSS of FIRST; the CWE catalog of MITRE, CWE Terms of Use. The text of the record is shown as published. Data sources and licences.
Vulnpocalypse