Siemens AG IEC 61850 system configurator, DIGSI 5 (affected as IEC 61850 system configurator is incorporated), DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer…

No CVSS score yet EPSS 1.81%

Published 9 Jul 2018 Updated 16 Sep 2024 CNA: siemens

Description

A vulnerability has been identified in IEC 61850 system configurator (All versions < V5.80), DIGSI 5 (affected as IEC 61850 system configurator is incorporated) (All versions < V7.80), DIGSI 4 (All versions < V4.93), SICAM PAS/PQS (All versions < V8.11), SICAM PQ Analyzer (All versions < V3.11), SICAM SCC (All versions < V9.02 HF3). A service of the affected products listening on all of the host's network interfaces on either port 4884/TCP, 5885/TCP, or port 5886/TCP could allow an attacker to either exfiltrate limited data from the system or to execute code with Microsoft Windows user permissions. Successful exploitation requires an attacker to be able to send a specially crafted network request to the vulnerable service and a user interacting with the service's client application on the host. In order to execute arbitrary code with Microsoft Windows user permissions, an attacker must be able to plant the code in advance on the host by other means. The vulnerability has limited impact to confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.

Exploitation

EPSS 1.81%: the probability of exploitation activity in the next 30 days, from the EPSS model of FIRST. The score is higher than 79.1% of all scored CVEs. Scores of 28 Nov 2026.

Weakness

Affected products

As the CNA lists them.

ProductVersions
IEC 61850 system configurator, DIGSI 5 (affected as IEC 61850 system configurator is incorporated), DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, SICAM SCC
affected IEC 61850 system configurator : All versions < V5.80
affected DIGSI 5 (affected as IEC 61850 system configurator is incorporated) : All…
affected DIGSI 4 : All versions < V4.93
affected SICAM PAS/PQS : All versions < V8.11
affected SICAM PQ Analyzer : All versions < V3.11
affected SICAM SCC : All versions < V9.02 HF3

Is my server affected?

This CVE is in IEC 61850 system configurator, DIGSI 5 (affected as IEC 61850 system configurator is incorporated), DIGSI 4, SICAM PAS/PQS, SICAM PQ Analyzer, SICAM SCC of Siemens AG, which Linux distributions and language package managers do not ship. The advisory of the vendor is in the references below.

Vulnpocalypse matches the package lists of Linux servers and containers against the Trivy vulnerability database, which does not list this product.

References

Advisories

Other references

Source: the record CVE-2018-4858 of the CVE List (CVE Program), CVE Terms of Use; EPSS of FIRST; the CWE catalog of MITRE, CWE Terms of Use. The text of the record is shown as published. Data sources and licences.